Mechanical Characterisics
REQUIREMENTS CHARACTERISTICS TEST METHOD(DIS C 5321)
Terminal Strength
(PULL)
No evidence of breakdown Terminals shall withstand a pull of 2.5Kgf in a horizontal direction for 5 sec.
Terminal Strength
(BEND)
No evidence of breakdown Terminals shall withstand a return bend of 250gf for 5sec at a right angle to the axis, while being repeated the same to the opposite direction
Body Strength No evidence of breakdown A load of 5Kgf for 10 sec.
Vibration Δ L/L shall be within ±5%.Q factor shall be 30 and over 2 hours in each direction of X,Y,Z on p-Board at a frequency range of 10-55-10Hz with 1.5mm amplitude.
Dropping No evidence of damage Dropping 1m over the ground of concrete or cement 10 times

Mechanical Characterisics
REQUIREMENTS CHARACTERISTICS TEST METHOD ( JIS C 5321 )
DC Superimposition Δ L/L within -10% Inductance, when the allowable current is applied, to be measured bye LCR - METER.
Rise in Temperature within 20°C A rise in temperature, when the allowable current is applied for 30 min., to be measured by a thermoelectric thermometer.
Over current Test No evidence of burning or flaming The current twice the allowable current to be applied for 5 min.
Resistance to Soldering Heat No evidence of outer damage Immerse in the solder ( H63A ) of 270±5°C for 5±0.5 sec.
Solderability More than 75% toward circumference to be covered with new soldering Immerse in the solder ( H63A ) of 230±5°C for 2±0.5 sec.
Dielectric with standing voltage No evidence of fuming,flaming or breakdown 500V 5 SEC. :V Block.
Insulation Resistance 1000 Mohm and over 500v 1 mim. :V Block.

Endurance Test
REQUIREMENTS CHARACTERISTICS TEST METHOD ( JIS C 5321 )
LOW TEMP. Characteristics Δ L/L within ±10%, Q:30 and over Leave for 1000hrs in a bath of TEMP.-25±2°C
Resistance of Heat Δ L/L within ±10%, Q:30 and over Leave for 1000hrs in a bath of TEMP.85±2°C
TEMP. Cycling Δ L/L within ±10%, Q:30 and over Keep for 30 min. at TEMP. of -25°C-+85°C at a5 cycle case of TEMP. change from low to high and V.V.,leave for 10-15 min at normal TEMP.
Temperature Characteristics Δ L/L within ±5% Δ L/L to be measured at the temperature of between -25°C and+85°C as based on the temperature of 20°C
Moisture Endurance Δ L/L within ±10% TEMP. 40±2°C,Humidity 90-95%1000 hrs
Endurance
(moisture load)
Δ L/L within ±10% Allowable current on for 1000 hrs continuously TEMP. 40±2°C Humidity:90-95%
Endurance(high temp. overload) Δ L/L within ±10% Allowable current on for 1000 hrs continuously at TEMP. of 85±2°C

Unless otherwise specified, measurements shall be performed within 2 hours after leaving test samples for more than one hour at the normal temperature and at the normal humidity .