| ITEM |
SPECIFICATION |
TEST METHOD |
| DC Resistance |
J: ±5%, F: ±1% |
JIS C 5202 5.1 |
Temperature Coefficient of Resistance(TCR) |
J: ±200ppm/°C F: ±100ppm/°C |
JIS C 5202 5.2 / IEC 115-1 4.8.4.2
T1 T2 Test temperature:25°C → -55°C
25°C → -55°C |
| Short Time Overload |
J: ΔR≤ ± (2%+0.1Ω) F: ΔR≤ ± (1%+0.05Ω) |
JIS C 5202 5.5 / IEC 115-1 4.13 2.5xRated voltage (Max. Overload Voltage) for 5 sec. measure resistance after 30 minutes |
Resistance to Solder Heat |
J: ΔR≤ ± (1%+0.1Ω) F: ΔR≤ ± (0.5%+0.05Ω) No mechanical damage |
JIS C 5202 6.4 / IEC 115-1 4.18 With 260 ± 5 °C for 10 ± 1 sec. |
| Solderability |
Over 95% of termination must becovered with solder |
JIS C 5202 7.4 / IEC 115-1 4.17 After immersing flux, dip in the 235 ± 5°C molten solder bath for 2 ± 0.5 sec. |
| Temperature Cycle |
J: ΔR≤ ± (1%+0.1Ω) F: ΔR≤ ± (0.5%+0.05Ω) No mechanical damage |
JIS C 5202 7.4 / IEC 115-1 4.19 Repeat 5 cycles as follow -55°C(30minutes)+25°C(10~15minutes) +125°C(30minutes)+25°C(10~15minutes) |
| Terminal Strength |
ΔR≤ ± (0.5%+0.05Ω) No mechanical damage |
JIS C 5202 6.1 500g for 10 seconds |
| Load Life |
J: ΔR≤ ± (3%+0.1Ω) F: ΔR≤ ± (1%+0.05Ω) |
JIS C 5202 7.10 / IEC 115-1 4.25.1 Permanent resistance change after 1000+48/-0 hours (1.5 hours ON,0.5hour OFF) at RCWV or Max. Keep the element at 70 ± 3°Cambient |
| Load Life Humidity |
J: ΔR≤ ± (3%+0.1Ω) F: ΔR≤ ± (1%+0.05Ω) |
JIS C 5202 7.9 / IEC 115-1 4.24.2 Maintain the temperature of the element at 40 ± 2 °Cand 90~95% RH with the rated voltage applied. Cycle ON for 1.5hours and Off for 0.5hour for 1000+48/-0 hours. After one hour, measure the resistance value. |
| Intermittent Overload |
ΔR≤ ± (5%+0.1Ω) No mechanical damage |
JIS C 5202 5.8 2.5xRated Voltage(Max. Overload Voltage), 1secON,25sec OFF, test 10,000 cycles |